10 Common Husqvarna 550 Xp Mark II Problems (With Fixes)

Are you facing issues with your chainsaw? The Husqvarna 550 XP Mark II is a powerful tool, but like any machine, it can encounter problems over time. 

In this guide, we’ll explore 10 common Husqvarna 550 XP Mark II problems and provide simple fixes to keep your chainsaw running smoothly. 

Let’s troubleshoot and get it back to peak performance!

Husqvarna 550 Xp Mark II Problems (Short Overview)

The Husqvarna 550 XP Mark II can face issues such as starting troubles, overheating, or chain tension problems. 

These problems often arise from improper maintenance or regular wear and tear. 

By inspecting the chainsaw regularly, cleaning it, and following recommended guidelines, you can fix these issues and keep it working like new.

Read 10 Common Problems With Fixes In Easy Ways…

husqvarna 550 xp mark ii problems

1. Starting trouble 

The Husqvarna 550 XP Mark II is a powerful chainsaw, but some users report starting issues. 

These problems can make it harder to get the saw running, delaying your work and causing frustration. 

Below, we’ll explore the common causes and the best fixes to keep your chainsaw running smoothly. 

Causes of Starting Trouble 

  • Clogged air filter restricting airflow. 
  • Faulty spark plug affecting ignition. 
  • Old or improper fuel causing engine issues. 

Fixes for Starting Trouble 

  • Clean or replace the air filter regularly. 
  • Inspect and replace the spark plug if necessary. 
  • Use fresh, high-quality fuel mixed to the correct ratio. 

2. Overheating issues 

The Husqvarna 550 XP Mark II is a powerful chainsaw, but overheating can be a common problem for users.

Causes of Overheating 

  • Clogged air filters blocking airflow 
  • Dust and debris in the cooling fins 
  • Overuse without proper maintenance 

Fixes for Overheating 

  • Clean or replace the air filter regularly 
  • Inspect and clean the cooling fins to improve airflow 
  • Take breaks during extended use to let the engine cool down 

3. Chain tension 

Chain tension problems are a common issue with the Husqvarna 550 XP Mark II. 

If the chain is too loose, it can derail during use, while an overly tight chain can cause excessive wear or even damage to the saw.

Causes 

  • Incorrect adjustment of the chain tensioning screw. 
  • Natural loosening of the chain after extended use. 

Fixes 

  • Regularly check and adjust the chain tension as per the manufacturer’s guidelines. 
  • Ensure proper lubrication to reduce friction and wear. 

4. Fuel efficiency 

The Husqvarna 550 XP Mark II is a powerful chainsaw, but some users report problems with fuel efficiency. 

This can lead to higher fuel consumption, making it less cost-effective for long tasks.

Causes of Fuel Efficiency Problems:

  • Clogged Air Filter: A dirty air filter restricts airflow, forcing the engine to use more fuel. 
  • Carburetor Issues: An incorrect carburetor setting can result in inefficient fuel use. 
  • Low-Quality Fuel: Using substandard fuel can affect performance and efficiency.

Fixes for Better Fuel Efficiency:

  • Clean the Air Filter: Regularly clean or replace your air filter to improve airflow. 
  • Adjust the Carburetor: Properly tune the carburetor for optimal fuel usage. 
  • Use High-Quality Fuel: Always use recommended, high-grade fuel to ensure better performance.

Read Also:

Husqvarna 545 mark ii problems

husqvarna 545 mark ii problems

5. Carburetor blockage 

One of the common problems with the Husqvarna 550 XP Mark II is carburetor blockage.

Causes 

Carburetor blockages are often caused by using dirty or old fuel, lack of regular maintenance, or debris buildup in the fuel system. 

Fixes 

To resolve this, clean the carburetor thoroughly using a carburetor cleaner and ensure the fuel you’re using is fresh and clean. 

Regular maintenance, such as replacing the fuel filter and using a fuel stabilizer, can help prevent future clogs. 

If the issue persists, consider consulting a professional technician.

6. Spark plug failure 

Spark plug failure is a common issue with the Husqvarna 550 XP Mark II and can lead to poor engine performance or trouble starting the chainsaw. 

A faulty spark plug often results from carbon buildup, wear and tear, or incorrect gaps.

Causes of Spark Plug Failure

  • Carbon deposits on the plug
  • Incorrect spark plug gap
  • General wear over time

Fixes for Spark Plug Problems

  • Clean or replace the spark plug regularly
  • Check and adjust the spark plug gap as per the manufacturer’s specifications
  • Use high-quality fuel and maintain the engine to prevent buildup

7. Oil leakage 

One common issue with the Husqvarna 550 XP Mark II is oil leakage.

Causes: 

  • Loose or damaged oil tank cap 
  • Cracked or worn-out oil lines 

Fixes: 

  • Ensure the oil tank cap is tightened securely after refilling. 
  • Inspect the oil lines for any wear or cracks, and replace them if needed. 
  • Regular maintenance can help prevent leaks and keep your chainsaw running smoothly. 

8. Air filter clogging 

One common issue with the Husqvarna 550 XP Mark II is air filter clogging.

Causes of Air Filter Clogging 

  • Excessive dust or sawdust from cutting 
  • Lack of regular maintenance and cleaning 

Fixes for Air Filter Clogging 

  • Clean the air filter regularly to remove dust and debris 
  • Replace the air filter if it’s worn or too dirty to clean 
  • Use a high-quality air filter compatible with the 550 XP Mark II 

9. Ignition problems 

If your Husqvarna 550 XP Mark II is having trouble starting or runs inconsistently, ignition issues might be the cause.

Common Causes 

  • Worn-out spark plug 
  • Defective ignition coil 
  • Loose or damaged wiring 

Fixes 

  • Replace the spark plug if it’s old or dirty. 
  • Test and replace the ignition coil if necessary. 
  • Inspect and repair any damaged wires. 

10. Vibration fatigue 

The Husqvarna 550 XP Mark II can sometimes experience vibration fatigue, which happens when the saw produces excessive vibrations during use. 

This can lead to discomfort for the operator and even wear and tear on the machine over time.

Causes of Vibration Fatigue 

  • Worn or damaged engine mounts 
  • Loose screws or parts 
  • Improper chain tension or bar alignment 

Fixes for Vibration Fatigue 

  • Replace worn engine mounts with new ones 
  • Check and tighten all screws and bolts 
  • Regularly inspect the chain and bar for proper alignment and tension 

FAQs

What does the Mark II mean with Husqvarna? 

The Mark II designation signifies an updated or improved version of an existing Husqvarna model. 

It often includes enhanced features, better performance, and increased durability compared to the original version. 

What is the weight of the Husqvarna 550 XP Mark II? 

The Husqvarna 550 XP Mark II weighs approximately 11.7 lbs (5.3 kg) without the cutting equipment attached.

Looking for the air filter for the Husqvarna 550 XP Mark II? 

The air filter for the Husqvarna 550 XP Mark II can be found at authorized Husqvarna dealers or online retailers. 

Make sure to choose a genuine replacement part for optimal performance and longevity. 

Husqvarna 550 XP Mark II vs. Stihl 261: Which one is better? 

Both models are excellent professional chainsaws, but the Husqvarna 550 XP Mark II excels in cutting speed and ergonomics, while the Stihl 261 offers reliable fuel efficiency and robust design. 

The choice ultimately depends on personal preference and specific use cases. 

SiteOwner